    advanta bed user manual

    Failure to observe this restriction can result in severe injury to people and serious damage to equipment. Chapter 6: General Procedures Cleaning, preventive maintenance, and other general procedures are described in this chapter.A variety of options are available, including nurse call, patient scale, a Patient Position Monitoring (PPM) system, night light, air system, and siderail controls.The automatic contour can only be activated from the patient siderail control panels, and not from the caregiver siderail control panels. The Trendelenburg angle indicator, located on the footboard control panel, displays the amount of Trendelenburg or Reverse Trendelenburg in degrees and inches. The head motor takes 30 seconds to resume its normal operation. To operate the CPR Release: Activate the CPR Release by pushing one of the red switches (A) on the side of the release handle (B), and pulling out on the handle (see figure 1-5 on page. The pedal controls can be accessed near the casters at each of the four corners of the bed. The pedals are clearly identified to distinguish between braking (orange) and steering (green). IV Rod Accommodation There are four locations where an IV rod can be installed—two at the head end, and two at the foot end. To store a siderail, lower it completely, then push it in under the bed surface. Always tug slightly on a siderail after adjusting it to ensure that it is securely locked in place. Press and release the appropriate heel relief switch (heel 1, heel 2, or heel 3). No additional electrical components, such as isolation transformers, are required to make this bed meet applicable electrical codes. The insulation materials are of the type that will not deteriorate to an unsafe level through normal use. They stop the motor automatically if it heats up to a certain temperature. The motor will not run again until the motor cools.

    • advanta bed service manual, advanta 2 bed user manual, advanta 2 bed service manual, advanta bed user manual, advanta bed user manual pdf, advanta bed user manual download, advanta bed user manual free, advanta bed user manual 2017, hill rom advanta bed user manual, hill-rom advanta bed user manual.

    Sign in Forgot Password. My Bench Close Sign In Not A Member. Sign Up Join MedWrench OK name type Receive Summary Emails. Designed for comfort. Hill-Rom’s Advanta bed is engineered to help reduce the likelihood of patient falls and offers the added benefit of an optional four-zone pressure reduction surface. While the Advanta bed was created to help address your patients’ needs, it also offers features that contribute to the safety and efficiency of caregivers. FORUMS View All (33) Ask a New Question 2 Replies -DannyFlVic a year ago a year ago Bed head section will not lower Having issues w bed not lowering head side beyond a certain point. Is there a technician in the Daytona Beach, FL area. Reply 1 Reply -frank81 3 years ago 3 years ago service mamual need a service manual Reply 1 Reply -Wiltdflower 3 years ago 3 years ago Bed wont go sown My sis was playing with buttons on bed. Now the bed will not go straight down. The bed goes in trendelenburg if you press the bed down button or will go And reverse trendelenburg if you press the bed up button.The bed is all the way up. It was working fine before.By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details. All Rights Reserved. P1600 For Parts or Technical Assistance man168ra USA (800) 445-3720 Canada (800) 267-2337 International: Contact your distributor. The information contained in this manual is subject to change without notice. Hill-Rom makes no commitment to update or keep current, the information contained in this manual. The only product warranty intended by Hill-Rom is the express, written warranty accompanying the bill of sale to the original purchaser. To order additional copies of this service manual, call (800) 445-3720, and place a parts order for part number man168ra. It also includes parts lists (in chapter 5) for ordering replacement components. Audience This manual is intended for use by only facility-authorized personnel.

    CAUTION: When handling electronic components, wear an antistatic strap. The fittings are plastic and can break if handled too roughly during the removal process. CAUTION: Failure to align the slide switch and drive screw when installing the hilow head drive screw can cause severe damage to the bed. If the hose becomes unattached during operation, equipment damage could occur. CAUTION: Align the slide switch and the head limit switch after servicing the head drive screw assembly. Failure to do so could result in personal injury or equipment damage. A common digital VOM is shown (see figure 2-1 on page 2-4).Note symptoms or other information concerning the problem that the operator describes. This information helps identify the probable cause. 1. The mechanical parts are operating correctly. Remove, replace, and adjust (if necessary) the damaged component(s).The resistance should be above 100K ohms. 3. Apply pressure to the PPM sensor, the resistance should go down as more pressure is applied. This only tests for power being switched to each valve or pump component to determine if a possible fuse has failed or other power failure. The circuits that fail will flash their corresponding LED for 7 seconds. Table 2-3. Air System Self-Diagnostic Test—Surface Power LED and Corresponding LED If Surface Power LED indicator is FLASHING: Corresponding circuit that has Lights this LED indicator on the FAILED footboard control panel. Otherwise, call Hill-Rom Technical Support at (800) 445-3720.Go to “Final Actions” on page 2-17.Replace or repair the damaged pins. Connect the connector. Otherwise, call Hill-Rom Technical Support at (800) 445-3720. 11. Go to “Final Actions” on page 2-17.CAUTION: To prevent component damage, ensure that your hands are clean, and handle the P.C. The voltage is greater than 8V DC. Otherwise, call Hill-Rom Technical Support at (800) 445-3720. 9. Go to “Final Actions” on page 2-17.

    See table 1-3 on page 1-25 through table 1-5 on page 1-27 for caregiver and patient control switches for the siderails, the caregiver control switches for the footboard control panel, and a list of whether the item is standard or optional. The back light can be turned on or off at the footboard control panel. The back light on the nurse call switches cannot be turned off. The head, knee, and hilow motors can be locked out in any combination, or all at once. Activation of the knee lockout also keeps the automatic contour function from working. To place a call on the nurse call system, press the nurse switch on any siderail control panel. A tone sounds to confirm that the call has been placed, and the yellow call indicator light on the patient’s siderail control panel illuminates. For A model beds: Turn on the system by simultaneously pressing and holding the enable switch and the mode switch. Hold any two volume switches, then press and release the third volume switch to change the tone. All the PPM indicator lights will begin to flash. Failure to do so could result in personal injury or equipment damage. SHOCK HAZARD: Do not expose the bed to excessive moisture. Personal injury or equipment damage could occur. SHOCK HAZARD: If fluid is spilled in the footboard area, unplug the bed from its power source. Preventive maintenance performed by unauthorized personnel could result in personal injury or equipment damage. WARNING: Tie the foot section back toward the head section when preparing to remove the foot end cover. Failure to disconnect line voltage to the bed can cause personal injury and damage the VOM. WARNING: Use a 2 x 4 to support the head end of the bed during this procedure. Failure to do so could cause the head end of the bed to fall resulting in person al injury or equipment damage. Operate the bed only with persons clear of mechanisms. CAUTION: To prevent component damage, ensure that your hands are clean and only handle the P.C. boards by their edges.

    board and the logic control P.C. board. This cable, with its multi-colored wires, is an exception to the single color rule. This interface is earth-ground-referenced. An AC line supply connector, P5, is provided for accessories or air system control P.C. The power supply provides a pre-regulated 12-14V DC referenced to signal VSS at 400mA maximum, 200mA typical, and another unregulated 9-18V DC referenced to signal chassis digital ground at 200mA. The analog circuitry is located in the weigh frame of the bed as close to the load beams as possible. The load beams are resistive bridge sensors excited by a regulated DC voltage. The relay is on continuously during normal operation. U15 can maintain regulation with an input voltage down to 5.75V DC. R46 scales the range of R63 pin 16 to the 2.90 volts described above. The remainder of the conversion instruction is sent by clocking in three more bits, 101, where 101 is the opcode for converting U4 CH 1 with respect to CH 0. Communications between the controller circuit and the pressure sensing circuit is via a 25 pin D-sub cable, utilizing 3-wire, synchronous, serial, bi-directional communications (along with other discrete lines, and AC and DC power). Pressure Relief Mode While in the pressure relief mode, the air pressures in each of the six bladder zones are regulated at predefined levels, called trim points. Auto Firm Mode While in the auto firm mode, all trim points are changed to new values. Pressures are then regulated, as described in the pressure relief mode, at the new trim points. However, the head and seat zones are inflated to these new values first. These failures cause the system to transfer to the off mode and repeatedly flash a code on the footboard control panel service required LED. Thoroughly dry the electrical connections for the footboard before plugging the bed into its power source. Personal injury or equipment damage could occur. Replacement 1. Install the footboard (A) on the mounting posts (B).

    CAUTION: To prevent component damage, ensure that your hands are clean, and handle the P.C. The voltage is greater than 100V AC. Perform the “Air System Self-Diagnostic Test”. Go to “Final Actions” on page 2-17. Failure to do so could result in personal injury or equipment damage. Otherwise, call Hill-Rom Technical Support at (800) 445- 3720. 7. Replace the air control P.C. board (refer to procedure 4.9). CAUTION: Wear an appropriate static strap when working with electronics. Equipment damage can occur. CAUTION: To prevent component damage, ensure that your hands are clean, and handle the P.C. If this solves the problem, go to “Final Actions” on page 2-17. Otherwise, call Hill-Rom Technical Support at (800) 445-3720. 5. Go to “Err0” on page 2-61, “Err1” on page 2-62, “Err2” on page 2-62, or “Err3”. An error has occurred during the memory check. If the Position LED is flashing, proceed to step 1. Exiting LED 14. The Exiting LED is flashing. See “Zeroing for the Out of bed Mode (Beds Without Scales) for beds without scales on page 1-34, or see “Zeroing the Scale”. Page 2 - 68. The Nurse Call light on the tester comes on when either switch is activated. NOTE: Pressing the Nurse Call switch from the siderail causes the call to be placed and then released, and is controlled by the bed system. Figure 3-11. Logic Board PN 63285 Refer to fold-out FO 3-7 at the rear of this manual. Figure 3-12. Figure 3-16. Sensor Board PN 4474001 Refer to fold-out FO 3-12 at the rear of this manual. Figure 3-17. Figure 3-21. Inner Patient II Board (B Model Beds) PN 67203 Refer to fold-out FO 3-17 at the rear of this manual. Figure 3-22. The outputs on connectors P7 and P12 are switched AC line voltages used to power the split-phase, AC, intermittent-duty motors. All inputs to the logic control P.C. board are processed simultaneously and present the motors with power when conditions are correct. The siderail cable, part number 63600, connects the siderail interface P.C.

    If the bed is unloaded too far, the hilow remote switch trips and the bed automatically rises for three seconds. Replacement 1. Install the brake light switch in the reverse order of removal. 2. Replacement 1. Replacement Install the siderails in the reverse order of removal. See “Scale Calibration” on page 6-3. See “Lubrication Requirements” on page 6-7. 5. If the siderails are frozen: a. Raise the siderail to the up position, or remove it from the bed completely. SHOCK HAZARD: Unplug the bed from its power source. CAUTION: To prevent component damage, ensure that your hands are clean and only handle the P.C. boards by their edges. CAUTION: When handling electronic components, wear an antistatic strap. SHOCK HAZARD: Unplug the bed from its power source. CAUTION: To prevent component damage, ensure that your hands are clean and only handle the P.C. SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could result in personal injury or equipment damage. CAUTION: To prevent component damage, ensure that your hands are clean and only handle the P.C. SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could result in personal injury or equipment damage. CAUTION: To prevent component damage, ensure that your hands are clean and only handle the P.C. Seat Section Panel Removal 8. Using the needle nose pliers, push the four drive rivets (C) securing the PPM sensors (D) to the bed, through the bed frame and PPM sensor (D). 9. PPM Sensor Removal NOTE: Do not remove the cable ties holding the cables in the electronics pan if possible. It is preferred to feed the sensor cable through the cable ties. 13. CAUTION: Ensure there are no sharp edges on the drive rivets. Equipment damage can occur. SHOCK HAZARD: Unplug the bed from its power source. If requested by Hill-Rom, products or parts for which a warranty claim is made shall be returned prepaid to Hill-Rom’s factory. This packet includes an RMA number, instructions, and a shipping label.

    If an RMA number is not available, obtain one by phoning Hill-Rom Technical Support at (800) 445-3720. Page 5 - 6. Do not confuse this price with your price. Do not return any parts without an RMA number.Air Supply Module Item Number Part Number Quantity Description 39763-04 (1600) 2 Standoff 987 (1600) Machine Screw 63909 (1600) Air system weld - assembly 47103 (1600) Muffler assembly 64095 (1600) Linear air pump 64096 (1600) Elbow fitting 19124 (1600) Footboard—P1606 Item Number Part Number Quantity Description 6371903 (1600) Cable assembly (black) 6371902 (1600) Cable assembly (red) 6371901 (1600) Cable assembly (white) 63344 (1600) 0 or 1 Scale display assembly (beds with scales) 6371904 (1600) Cable assembly (blue) 4214101 (1600) Head Drive Screw Assembly Item Number Part Number Quantity Description 43272S (1600) Head drive screw assembly 3517 (1600) Roll pin 42141 (1600) Hilow screw 66266S (1600) Clip engagement 61991 (1600) Slide switch assembly 42845 (1600) Lift nut. Electronics Module Assembly Item Number Part Number Quantity Description 45916 (1600) Test port lid 45915 (1600) Test port box 63208 (1600) P.C. board assembly, inner patient switch 63600 (1600) Siderail interface cable (A model beds) 6010802 (1600) Cable 64027 (1600) The software does not allow the user to key in weights outside of this range. NOTE: When the display reads CAL1, the bed is zeroed. 8. When one tone sounds, add the calibration weight to the left foot section. 9. Cleaning SHOCK HAZARD: Follow the product manufacturer’s instructions. Failure to do so could result in personal injury or equipment damage. SHOCK HAZARD: Unplug the unit from its power source. Failure to do so could result in personal injury or equipment damage. To loosen heavy, dried-on soil, you may first need to saturate the spot. Disinfecting When there is visible soilage and between patients, we recommend that you disinfect the unit with a tuberculocidal disinfectant.

    NOTE: The footboard connectors are keyed so that footboards will fit easily on the correct beds. SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could result in personal injury or equipment damage. Replacement CAUTION: Do not lower the foot section while the knee section is down and the foot end cover is removed. Failure to do so could result in personal injury or equipment damage. 5. Install the footboard (see “Footboard” on page 4-7) on the bed. 6. Failure to do so could result in personal injury or equipment damage. 2. Unplug the bed from its power source. 3. SHOCK HAZARD: Unplug the bed from its power source. Damage can occur to the pressure switches. Failure to do so could result in personal injury or equipment damage. 1. Failure to do so could result in personal injury or equipment damage. CAUTION: When handling electronic components, wear an antistatic strap. Failure to do so, could result in component damage. Failure to do so could result in personal injury or equipment damage. NOTE: Ensure that the air tubes are connected to their corresponding valves. 2. SHOCK HAZARD: Unplug the bed from its power source. CAUTION: When handling electronic components, wear an antistatic strap. Failure to do so, could result in component damage. SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could result in personal injury or equipment damage. Replacement 1. SHOCK HAZARD: Unplug the bed from its power source. SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could result in equipment damage. CAUTION: Be careful not to damage the cables when removing the footboard control panel. Detach the lower end of the cable conduit from the retracting frame. 13. Cut the wire ties. 14. Remove the screw and clamp attaching the power cable (F) to the bed frame. SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could result in personal injury or equipment damage.

    SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could result in personal injury or equipment damage. SHOCK HAZARD: Unplug the bed from its power source. Ensure that the CPR latch assembly properly actuates the limit switch. Damage to the bed can occur. 10. Failure to do so could cause the head end of the bed to fall, resulting in personal injury or equipment damage. If the bed is unloaded too far, the hilow remote switch trips and the bed automatically rises for three seconds. Remove the hilow head drive screw assembly (J) from the bed. Replacement 1. Install the hilow head drive screw assembly (J) on the bed, making sure that the screw (I) goes into the keyhole slot. CAUTION: Do not over-tighten the limit switch mounting screws. Over-tightening the mounting screws could cause the limit switch to malfunction. 2. Over-tightening the mounting screws can cause the limit switch to malfunction. 3. Failure to do so could cause the head end of the bed to fall, resulting in personal injury or equipment damage. If the bed is unloaded too far, the hilow remote switch trips and the bed automatically rises for three seconds. Failure to do so could result in personal injury or equipment damage. 4. Unplug the bed from its power source. 5. SHOCK HAZARD: Unplug the bed from its power source. Failure to do so could cause the foot end of the bed to fall, resulting in person al injury or equipment damage. If the bed is unloaded too far, the hilow remote switch trips and the bed automatically rises for three seconds. Using the screwdriver if necessary, remove the hilow straps (O) from the torque cage (P). 16. Slide the hilow foot drive screw assembly toward the head end of the bed until the screw (I) can be lifted from the keyhole slot. Install the seat section cover (see “Air Control Cover” on page 4-15). 13. Install the foot end cover (see “Foot End Cover” on page 4-9). 14. Plug the bed into an appropriate power source. 15.

    Preventive maintenance performed by unauthorized personnel could result in personal injury or equipment damage.Knee limits Run the knee section to the full upper and lower limits to ensure proper function of the limit switches. Pivot points Lubricate all pivot points on the bed. CPR release Test the CPR release for proper operation and reset of the head screw drive. Adjust the CPR release if necessary (see “CPR Release Handle”. We recommend that you perform annual preventive maintenance (PM) and testing for Joint Commission on Accreditation of Healthcare Organizations (JCAHO). Check the switch LEDs and the LED information indicators for proper operation. Failure to do so could result in personal injury or equipment damage. 1. Unplug the bed from its power source. 2. Lift the foot section (B) to access the air hose coupling (D) and cable connector (C) (see figure 7-1 on page 7-4). Failure to do so could result in personal injury or equipment damage. 1. Comfortline Basic is a registered trademark of Hill-Rom Services, Inc. Comfortline Ultimate is a registered trademark of Hill-Rom Services, Inc. Hill-Rom is a registered trademark of Hill-Rom Services, Inc. PLEUR-EVAC is a registered trademark of Deknatel, Inc. SideCom is a registered trademark of Hill-Rom Services, Inc. ZoneAire is a registered trademark of Hill-Rom Services, Inc. The information contained in this manual is subject to change without notice. The only product warranty intended by Hill-Rom is the express, written warranty accompanying the bill of sale to the original purchaser. Hill-Rom makes no other warranty, express or implied, and in particular, makes no warranty of merchantability or fitness for a particular purpose. Additional copies of this manual can be obtained from Hill-Rom. To order additional copies of this manual, call (800) and place a parts order for part number usr017rb.

    Revision Letter Pages Affected Date Original Issue December, 1999 A All April, 2001 B All September, 2002 Note the following examples: Standard text used for regular information. Boldface text emphasizes a word or phrase.The symbol below highlights a WARNING or Warning and Caution A WARNING identifies situations or actions that may affect patient or user safety. Disregarding a warning could result in patient or user injury. A CAUTION points out special procedures or precautions that personnel must follow to avoid equipment damage. The symbol below highlights a CAUGHT HAZARD WARNING: Caught Hazard Warning The symbol below highlights a CHEMICAL HAZARD WARNING: Chemical Hazard Warning The symbol below highlights an ELECTRICAL SHOCK HAZARD WARNING: Electrical Shock Hazard Warning 1 Accuracy of the scale may be diminished if the patient weighs more than 400 lb (181 kg). Mattress interface pressure performance may be diminished if the patient weighs more than 300 lb (136 kg). WARNING: Do not use the product outside the recommended patient height, width, and weight ranges. Patient injury or equipment damage may occur. 3 The following tables list the caregiver controls for the siderails and footboard, and the patient controls for the siderails. The tables also indicate whether the item is standard or optional. The patient siderail controls are on the inner sides of the head end siderails. 4 When activated, the CPR Release automatically lowers the head section of the bed to the flat position, enabling emergency procedures to be performed without unnecessary loss of time. After the head section is down, the knee section also comes down to the flat position. On beds equipped with an integrated air surface (ZoneAire Sleep Surface), the Auto Firm function engages automatically when the CPR Release is activated. This provides a firm surface that supports a CPR board. The headboard of the Advanta Bed can be used as a CPR board in emergencies.

    Emergency CPR Release Button Location: On both sides of the head section, near the head end of the bed. To Activate: Press the red button on either side of the CPR Release handle, and pull the handle. Release your hand as the head section begins to come down. WARNING: If electrical power is lost, the head section still lowers, but the Auto Firm function does not engage. The optional air mattress maintains the same air pressure it had before power loss. The effectiveness of the CPR board may be reduced. Emergency CPR Release Handle If electrical power is lost, the air mattress maintains the same level of pressure it had at the time of power loss. If electrical power is lost, the knee section, if raised, cannot be lowered. Do not use the CPR Release to lower the head section in non-emergency situations. Use the Head Down controls located on the siderail. After activating the CPR Release, allow 30 seconds for the head motor to resume its normal operating position before using the Head Up or Head Down controls. 6 WARNING: Unplug the bed from its power source before inserting the IV rod for manual operation. Unexpected resumption of power can cause the IV rod to rotate and cause injury. Location: Access hole at the head end of bed. To Reset: Insert a Hill-Rom P2217 IV rod into the access hole at the head end of bed until it engages the roll pin in the end of the screw assembly. Push the IV rod hard enough to push the ejection spring back from the roll pin, allowing the IV rod to engage. Turn the IV rod clockwise until the screw assembly reaches its mechanical stop (you should hear a click). The head section will not raise during this procedure. IV Pole Insertion Points for Manual Operation WARNING: Remove the IV rod before plugging the bed into an appropriate power source. Resumption of power can cause the IV rod to rotate and cause injury. Remove the IV rod from the head screw assembly. Plug the bed into its appropriate power source.

    Hold the CPR release in the activated position until the motor stops running. The bed is now operational. Central Brake and Steer The Advanta Bed is equipped with 4-wheel braking and 2-wheel steering. The pedal controls can be accessed near the casters at each of the four corners of the bed. Steering the Advanta Bed 7 When the brakes are not engaged, the casters rotate, and the Brake Not Set indicators flash continuously. Location: At each caster on the bed. To Activate: At any wheel, push down fully on the orange pedal (the one closest to the head end of the bed). When the Brake Not Set indicator goes out, the brakes are locked. Unless the bed is about to be moved, the brakes should always be set and locked. After setting the brakes, try to move the bed slightly to ensure that the brakes are locked. When the brakes are not locked, the Brake Not Set indicators flash continuously. Central Brake and Steer Braking Steering The 2-wheel steering system locks both foot end casters in a straight position for easier transport. To Activate: At any wheel, push down fully on the green pedal (the one closest to the foot end of the bed). The Brake Not Set indicators will start to flash. Central Brake and Steer Steering During patient transport and in steer mode, push the Advanta Bed from the head end, using the headboard handles as hand holds. 8 This function is used for exact positioning of the bed and maneuvering in confined areas Location: At each caster on the bed. To Activate: At any wheel, push either the orange or green pedal down slightly until the pedal is flat (in a horizontal position). Central Brake and Steer Neutral Bed Functions The Advanta Bed is equipped with standard bed function controls on the caregiver side of each head end siderail, and at the footboard control panel. These controls operate all of the motor functions of the bed. Location: Outside left siderail, outside right siderail, footboard control panel.

    To Activate: Press and hold the Bed Up key to raise the bed. Press and hold the Bed Down key to lower the bed. WARNING: Leave the bed in the low position when the patient is unattended. This can reduce the possibility of patient falls and the severity of any resultant injuries. The Bed Not Down indicator illuminates when the bed is not in the lowest position. 9. The head section of the bed can be raised to any desired angle of inclination up to 65. Using the head angle indicator (see Head Angle Indicator on page 27), you can raise or lower the head section to specific desired angles. Location: Outside left siderail, outside right siderail; left patient siderail, right patient siderail. To Activate: Press and hold the Head Up key to raise the head section of the bed. Press and hold the Head Down key to lower the head section of the bed. Advanta Bed with Head Section Raised Head Angle Indicators, located on the caregiver sides of the head end siderails, display the amount of head section angle in degrees. For the caregiver s convenience, the automatic contour function is only activated from the patient siderail controls. When the Head Up control is activated from the patient siderail controls, the automatic contour function is activated. This raises the knee section automatically up to 15 when the Head Up function is activated. The automatic contour function helps keep the patient from sliding towards the foot end of the bed. This function is not activated from the caregiver controls, but is accessible to caregivers by using the patient siderail controls. Alternatively, the caregiver can simultaneously press the head up and knee up controls. Do not manually lift or lower the head section with the CPR release handle. If you do, the head section will not elevate properly until it is reset. Damage to the bed can occur when the head section is lifted with the CPR release handle. To Activate: Press and hold the Knee Up key to raise the knee section of the bed.